GREENSTAR 24I JUNIOR MANUAL PDF

adminComment(0)
    Contents:

Hardware/Literature pack. Item. Qty. Greenstar 24i Junior/28i Junior Installation/ Servicing Instructions Users Instructions. INSTRUCTIONS. WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER. GREENSTAR 24i/28i JUNIOR. 1W o. FOR SEALED. WORCESTER BOSCH GREENSTAR 24i/28i Junior. 8 Installation instructions and any misuse or unauthorised modifications to the boiler.


Greenstar 24i Junior Manual Pdf

Author:WANDA JOWELL
Language:English, Japanese, German
Country:Nepal
Genre:Personal Growth
Pages:445
Published (Last):03.03.2016
ISBN:794-8-22909-662-9
ePub File Size:15.76 MB
PDF File Size:13.10 MB
Distribution:Free* [*Registration needed]
Downloads:38159
Uploaded by: BELEN

THE GAS METER. Read the instructions before starting work - they have been written to make the installation easier and prevent hold-ups. Worcester supports. NATURAL GAS: WORCESTER GREENSTAR 24i junior GC NUMBER Greenstar 24i Junior/28i Junior Installation/Servicing Instructions 1. View and Download Worcester GREENSTAR 24i junior instruction manual online . wall hung RSF gas-fired GREENSTAR 24i junior Boiler pdf manual download.

It' s compatible with Worcester' s Greenstar condensing combi and system boilers. Put a temperature control on maximum on a user control. These instructions are applicable to the Worcester, Bosch Group boiler model stated on.

Just click on the model or the Gas council number and the manual will download at the bottom of the page. Worcester Boiler Manuals.

Greenstar 28 i Junior Combi Operating Instructions. Boilers in the United Kingdom. Listed below are all the manuals for Worcester.

Enhancing on the popular features of the Greenstar i Junior. Hot water can also be poured onto the pipe from a watering can or similar container. Once the pipe has been thawed the boiler must be reset, press the reset button for five seconds and wait two to three minutes for the boiler to restart. If the boiler does not restart, contact Worcester s Technical Support Team for assistance.

Contact your installer in order to find a permanent solution to the problem. Specialist Service Engineers are available to attend a breakdown occurring on this boiler. Invoices for attendance and repair work carried out on this boiler by any third party will not be accepted. Reasonable evidence of this must be supplied on request.

A call-out charge will be made where: The boiler has been installed for over 4 months. Evidence cannot be provided that the first year service inspection has been carried out i. Our Field Service Engineer finds no fault with the boiler. In the case of a suspected fault, refer to the fault finding section of this guide. The gas supply to the burner is controlled according to the level of demand for heat.

The boiler operates with a low flame if the demand for heat reduces. The technical term for this process is modulating control. Modulating control reduces temperature fluctuations and provides an even distribution of heat throughout the home. This means that the boiler may stay on for relatively long periods of time but will use less gas than a boiler that continually switches on and off.

The system must be balanced correctly and the radiators may need upgrading. This allows the boiler to condense as much as possible for the central heating system. The temperature of each room can be set individually except primary room with the room thermostat using the thermostatic radiator valves. The minimum level of control is a programmer, interlocking room thermostat and thermostatic radiator valves.

Replace any old insulation with new insulation, preferably of around 00 mm thickness or more. Consideration should be given to replacement with PVCu or wooden framed double glazed units. Shelves fitted above or in front of the radiator should also be avoided.

It is advisable to manually adjust all thermostatic radiator valves every - 3 months to prevent them sticking.

Ensure radiator valves are correctly set and not damaged. However, always ensure that the curtains do not drape over radiators. During the period of this guarantee any components of the boiler which are proven to be faulty or defective in manufacture will be exchanged or repaired free of charge by Bosch Thermotechnology Ltd.

The householder may be asked to prove the date of installation, that the boiler was correctly commissioned and, where appropriate, the first year s service has been carried out to the satisfaction of Bosch Thermotechnology Ltd.

These should be part of the Benchmark Checklist.

Bosch GREENSTAR 28i junior User Manual

The boiler has been used only for the normal domestic purposes for which it was designed. This guarantee does not affect your statutory rights.

Model Serial No. The quality of our products, their economy and environmental safety are all of equal importance to us and all environmental protection legislation and regulations are strictly observed.

We use the best possible technology and materials for protecting the environment taking account of economic considerations.

All of our packaging materials are environmentally compatible and can be recycled. The various assemblies can be easily dismantled and synthetic materials are marked accordingly.

Assemblies can therefore be sorted by composition and passed on for recycling. If the top of a radiator is at a lower temperature than the bottom then it should be vented by releasing air through the venting screw at the top of the radiator. Ask your installer to show you how this is done. This boiler is fitted to a sealed system. Should water leaks be found or if excessive venting is required, then a service engineer must be contacted to inspect the installation and rectify any fault.

Only additives that are compatible with aluminium may be used in the system. Any incompatible additive used will invalidate the guarantee. Pluming and Condensate drain This is a condensing boiler and the flue terminal will, at times give out a plume of water vapour.

This is quite normal. The boiler produces condensate which is discharged regularly by a syphon within the boiler via a plastic pipe to a drain. This pipe must not be blocked or altered in any way. Most people set their Worcester Bosch boiler to come on in the morning just before they get up, they then set the timer to turn the boiler off just before they leave for work.

Need some help?

At Direct Heating Spares we offer a wide range of Worcester boiler parts, This page contains links to all of the free Worcester boiler manuals we have on our system. Ive got an old Worcester 24i combi boiler with a timer built into the unit, NOT a digital timer. To view the associated documentation and manuals for your boiler, please select from a category below.

To programme the heating this is what I do - Press select until the time in the window flashes, the wording down the right hand side shows if this is a time when the heating is on or off. These have little tappits round the outside that you either push in or leave where they are. Found the instruction manual on the worcester- bosch website but theres no mention of the timer. Boiler in full working condition and recently repaired by Corgi engineer but now the timer has stopped.

Worcester 24i boiler manual timer for sprinkler. Worcester Boiler Manuals. Unfollow worcester 24i timer to stop getting updates on your site feed.

New refers to a brand- new, unused, unopened, undamaged item, while Used refers to an item that has been used previously.

Worcester bosch combi boiler rsf I have heating but no hot water.

GREENSTAR 24i Junior/28i Junior

How to set timer on boiler worcester 24i junior? This boiler is now discontinued by the manufacturer but can still be used in the Comparison Tool. I don' t have a Worcester boiler but I do have a Worcester controller for my heating system.

The company prides itself on manufacturing boilers to the strictest quality control standards throughout every stage of production. Worcester Bosch has led the field in innovative appliance design and performance for more than 40 years.

If i remember right in is for on and out for off. Worcester 28i Junior. Find great deals on site for worcester 28i timer and robin. Timer failed on worcester greenstar 28i. Call Now Onor use the form and we will get straight back to you. My worcester combie rsf boiler has a 7 day electric timer with a digital display i need to adjust the the settings were can i find this information?When the needle reaches between to. It confirms that the boiler has been installed and commissioned according to the manufacturers instructions.

This does not affect your statutory rights. Unfollow worcester 24i timer to stop getting updates on your site feed. Boiler Manuals for the Worcester 28I appliance.

LAURI from Clarksville
I enjoy reading comics lovingly . Look over my other posts. I enjoy bicycle polo.
>